Manufacturer: Sony
 
Model: MJ100 & MJ110
 
Power supply: MJ100 - 5V (4.5 to 8V), MJ110 - 12V to 30V (11 to 31V)
 
Power consumption: MJ100 - 4W, MJ110 - 3W
 
Output interface: MJ100 - Line driver (RS422), MJ110 - Open collect (IOL = 50mA max)
 
Output type: A/B/Z phase (MJ100 also outputs U/V/W phase)
 
Reference points: External reference, SET P16
 
Measuring system: Magnetic
 
Number of divisions: 40 to 1000
 
Max response speed: Varies with frequency, read head and number of divisons
 
Output cable (connector): Supplied
 
 
 
 
The MJ100 and MJ110 interpolator units are component parts of the Sony Digiruler measuring systems. They are used in conjunction with Sony SL tape scales and PL25 or PL60 reading heads. At maximum interpolation setting the units provide 5µm or 2µm resolution output depending on the Sony scale and head combination used. The MJ100 provides line driver output, the MJ110 open collect.